Four numbers.
Four different jobs.
A single “800 N·m” headline cannot tell you whether a joint will move continuously, survive a transient or meet your required output speed.
A transient reference for start-stop conditions. It is not the torque you should use as a continuous operating rating.
The maximum permissible average load torque listed for the robot application scenario. Your real load spectrum still needs validation.
The table’s industrial reference value at 2,000 rpm input divided by the reduction ratio—not a universal rating for every duty.
The listed output speed with 1/2 rated torque. It must be assessed together with your required motion profile.
All five PM-H170 ratios.
Use this table to narrow the discussion, then confirm the final specification and operating conditions against manufacturer documents.
| Ratio | Start-stop peak torque N·m | Robot mean load limit N·m | Industrial rated torque¹ N·m | Rated speed² rpm |
|---|---|---|---|---|
| 51 : 1 | 497 | 242 | 169 | 22 |
| 81 : 1 | 641 | 351 | 255 | 15 |
| 101 : 1 | 702 | 460 | 328 | 12 |
| 121 : 1 | 762 | 557 | 363 | 10 |
| 161 : 1 | 800 | 557 | 363 | 7 |
¹ At 2,000 rpm input divided by reduction ratio.
² With 1/2 rated torque. Preliminary supplier reference data.
121:1 and 161:1:
what changes—and what does not.
762 N·m at 121:1 becomes 800 N·m at 161:1.
Both ratios list 557 N·m.
Both ratios list 363 N·m under the table’s reference condition.
The listed speed falls from 10 rpm to 7 rpm with 1/2 rated torque.
Output speed matters and the calculated duty fits.
It preserves the same listed mean-load and industrial rated-torque values as 161:1, with a higher listed rated speed. The lower peak figure still needs to cover your actual transient requirement.
Its specific peak-torque margin solves a real need.
The additional 38 N·m may be useful for the relevant start-stop condition—but only if 7 rpm meets the motion requirement and the other limits remain acceptable.
If the project needs speed, that choice can add a trade-off without increasing the listed mean-load or industrial rated-torque limits.
Send the duty,
not just a ratio.
These inputs make a configuration review more useful and reduce the chance of comparing the wrong operating conditions.
Start with your application